Electromagnetic compatibility (EMC) is the branch of electrical sciences which studies the unintentional generation, propagation and reception of electromagnetic energy with reference to the unwanted effects (Electromagnetic interference, or EMI) that such energy may induce. EMC aims to ensure that equipment items or systems will not interfere with or prevent each other's correct operation through spurious emission and absorption of EMI. EMC is sometimes referred to as EMI Control, and in practice EMC and EMI are frequently referred to as a combined term "EMC/EMI".

Filter: 
EM TEST AUTOWAVE Automotive Waveform Generator
EM TEST AUTOWAVE Automotive Waveform Generator
Battery simulation becomes more and more an issue in today´s automotive testing. Waveforms are getting more and more complex. Standardized single phenomena like cranking are still tested but real-life signals are of even higher interest for tes... View Details >>
EM TEST CN 200N1 Audio Transformer Assembly for LF Conducted Immunity
EM TEST CN 200N1 Audio Transformer Assembly for LF Conducted Immunity
The CN 200N1 is a standalone coupling network unifying two audio transformers being individually configurable for various test requirements (e.g. Ford EMC-CS-2009.1, German Lloyd GL VI-7-2 and SAE J1113-2). The CN 200N1 is used to apply the test sign... View Details >>
EM TEST CNI 501x 1-Phase Coupling/Decoupling Networks EFT/Burst 10 kV
EM TEST CNI 501x 1-Phase Coupling/Decoupling Networks EFT/Burst 10 kV
The single phase coupling/decoupling networks of the CNI 501x-series are used to couple EFT/Burst pulses and Surge pulses on to AC and/or DC supply lines. The CNI 501x-series coupling/decoupling networks are built fully complying with the standa... View Details >>
EM TEST CNI 503x 3-Phase Coupling/Decoupling Networks EFT/Burst 10 kV
EM TEST CNI 503x 3-Phase Coupling/Decoupling Networks EFT/Burst 10 kV
The three-phase coupling/decoupling networks of the CNI 503x series are used to couple EFT/Burst pulses and Surge pulses on DC-lines or to three-phase (4-wire or 5-wire supply lines) mains supply systems for voltages up to 1,000VDC / 3x690VAC. This i... View Details >>
EM TEST CNI 508N2 Coupling Network Shielded/Unshielded Lines 1 GBit/s
EM TEST CNI 508N2 Coupling Network Shielded/Unshielded Lines 1 GBit/s
The EM TEST CNI 508N2 is the first coupling/decoupling network available on the market to couple Surge onto shielded and unshielded high-speed communication lines with data rates up to 1,000MBit/s. Additionally, the CNI 508N2 can be used as a coupl... View Details >>
EM TEST CNV 504N / CNV 508N8 Coupling/Decoupling Networks
EM TEST CNV 504N / CNV 508N8 Coupling/Decoupling Networks
Surge pulses or Ringwave pulses are applied to unshielded unsymmetrical interconnection lines (signal/data lines) by means of standalone coupling/decoupling networks. For such testing EM TEST offers a range of CNVs for either 4 or 8 signal/data lines... View Details >>
EM TEST CNV 504N5 Coupling/Decoupling Networks 4 Signal / Data Lines
EM TEST CNV 504N5 Coupling/Decoupling Networks 4 Signal / Data Lines
The CNV 504N5-series coupling/decoupling networks are used to apply damped oscillatory waves onto signal/data lines in accordance to EN/IEC 61000-4-18. A capacitance of 0.5uF is specified to couple the pulses on to the lines. Each line has a decoupli... View Details >>
EM TEST CNV 508N4 Coupling/Decoupling Networks 4 Pairs / 8 Lines
EM TEST CNV 508N4 Coupling/Decoupling Networks 4 Pairs / 8 Lines
The CNV 508N4 series are special coupling/decoupling networks being used to perform "Electrical disturbance tests for measuring relays and protection equipment" in accordance to IEC 60255-22-1. A capacitance of 0.5uF is specified to couple ... View Details >>
EM TEST Coupling Networks IEC/EN 61000-4-6 EN 60945 CISPR 15/EN 55015
EM TEST Coupling Networks IEC/EN 61000-4-6 EN 60945 CISPR 15/EN 55015
Immunity test to conducted disturbances, induced by radio-frequency fields according to the standards IEC/EN 61000-4-6 and IEC/EN 60945 introduce different types of coupling/decoupling networks according to the characteristics of the interconnection ... View Details >>
EM TEST CWS 500N1 Continuous Wave Simulator 80W
EM TEST CWS 500N1 Continuous Wave Simulator 80W
The CWS 500N1 is the most compact single box test equipment for testing conducted rf immunity as per IEC 61000-4-6 and related standards with a frequency range of 100kHz to 300MHz. Apart from the 1kHz 80% AM signal the CWS 500N1 also generates a 2 Hz... View Details >>
EM TEST CWS 500N2 Continuous Wave Simulator EN/IEC 61000-4-6
EM TEST CWS 500N2 Continuous Wave Simulator EN/IEC 61000-4-6
Bulk Current Injection (BCI) is a test procedure to proof the immunity to electrical disturbances by narrowband electromagnetic energy. The test signal is injected by means of a current injection probe physically being a current transformer laid arou... View Details >>
EM TEST CWS 500N3 Continuous Wave Simulator 10 Hz – 250 kHz
EM TEST CWS 500N3 Continuous Wave Simulator 10 Hz – 250 kHz
The CWS 500N3 is the state-of-the-art solution in a compact single-box design to test the immunity to conducted low-frequency disturbances and low-frequency magnetic fields. The CWS 500N3 includes a LF signal generator and amplifier, a low-frequency ... View Details >>
EM TEST DPA 500N Digital Power Analyzer Harmonics & Flicker Test
EM TEST DPA 500N Digital Power Analyzer Harmonics & Flicker Test
Harmonics and interharmonics are caused by modern electronic power conditioning modules. Such, mostly non-linear, modules to control loads and to reduce power consumption is the source of voltage at unwanted frequencies superposed on the supply volta... View Details >>
EM TEST DPA 503N Digital Power Analyzer Harmonics & Flicker Test
EM TEST DPA 503N Digital Power Analyzer Harmonics & Flicker Test
Harmonics and interharmonics are caused by modern electronic power conditioning modules. Such, mostly non-linear, modules to control loads and to reduce power consumption is the source of voltage at unwanted frequencies superposed on the supply volta... View Details >>
EM TEST NETWAVE Series (1 Phase) Multifunctional AC/DC Power Sources
EM TEST NETWAVE Series (1 Phase) Multifunctional AC/DC Power Sources
The NetWave series (1-phase) are single phase AC/DC power sources, specifically designed to meet the requirements as per the standards IEC/EN 61000-4-13, -4-14 and -4-28. Used as a DC power source it covers the requirements as per the standards IEC/E... View Details >>
EM TEST PFS 200N Automotive Fail Simulator
EM TEST PFS 200N Automotive Fail Simulator
The PFS 200N Automotive Power Fail simulator is used to comply with standard requirements, mainly from vehicle manufacturers, to perform fast voltage dips ad drops (micro-interruptions). Some standards specify very fast rise and fall times below 1 mi... View Details >>
EM TEST PFS 503N Series Power Fail Simulators
EM TEST PFS 503N Series Power Fail Simulators
Electronic and electrical equipment may be affected by voltage dips, short interruptions and voltage variations of the power supply. Dips and interruptions are caused by faults in the public supply network, in installations or by sudden large change ... View Details >>
EM TEST UCS 500N5P Power Fail Simulator EN/IEC 61000-4-11 & 4-29
EM TEST UCS 500N5P Power Fail Simulator EN/IEC 61000-4-11 & 4-29
The UCS 500N5P is the new dedicated single-phase PowerFail simulator based on the successful UCS 500N series of ultra-compact simulators. Offering all the benefits of the well-known UCS 500N5 it is designed as a PowerFail simulator only. This makes i... View Details >>
EM TEST VDS 200N Series Voltage Drop Simulator & DC Voltage Source
EM TEST VDS 200N Series Voltage Drop Simulator & DC Voltage Source
The VDS 200N series is used to simulate the various battery supply waveforms recommended by international standards and by car manufacturer requirements. Especially the manufacturer requirements are an important area covered by the VDS 200N series as... View Details >>
EMC Partner ESD3000 ESD SIMULATOR 30 kV
EMC Partner ESD3000 ESD SIMULATOR 30 kV
ESD3000 is a light weight, hand-held battery operated tester. The modular construction enables many different test standards to be performed by simply changing the module. A broad range of accessories enable testing to many applications for contact d... View Details >>
ETS Lindgren 3701 Line Probe 10 kHz – 30 MHz
ETS Lindgren 3701 Line Probe 10 kHz – 30 MHz
The ETS Lindgren 3701 Line Probe is based on the FCC specified design for a line probe measuring conducted emissions in the frequency range of 10 kHz to 30 MHz. Its principal application as per FCC/OST MP-4 and ANSI C63.4-1981 is for those situat... View Details >>
ETS-Lindgren 3810-2 LISN 9 kHz - 30 MHz
ETS-Lindgren 3810-2 LISN 9 kHz - 30 MHz
EMCO'S LISN MODELS 3810/2 is a multi-line low pass filter networks used for conducted emissions measurement. It is placed between the power mains and the EUT (Equipment Under Test) to stabilize line impedance, provide a 50 ohm RF connection, ... View Details >>
ETS-Lindgren 5402 GTEM Test Cell
ETS-Lindgren 5402 GTEM Test Cell
ETS-Lindgren's GTEM! ™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle. B... View Details >>
ETS-Lindgren 5405 GTEM Test Cell
ETS-Lindgren 5405 GTEM Test Cell
ETS-Lindgren's GTEM! ™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle. B... View Details >>
ETS-Lindgren 5407 GTEM Test Cell
ETS-Lindgren 5407 GTEM Test Cell
ETS-Lindgren's GTEM! ™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle. B... View Details >>
ETS-Lindgren 5411 GTEM Test Cell
ETS-Lindgren 5411 GTEM Test Cell
ETS-Lindgren's GTEM! ™ Test Cell enables users to perform radiated emissions and radiated immunity tests in less time than at either an OATS or in a chamber. Tests can be performed quickly and accurately throughout the product life cycle. ... View Details >>
ETS-Lindgren HI-4416 Numeric EMF Readout Unit
ETS-Lindgren HI-4416 Numeric EMF Readout Unit
The HI-4416 Numeric EMF Readout is a versatile device for use with HI-44XX series, HI-3702 and HI-3638 fiber optically coupled electric and magnetic field probes. The optical isolation minimizes field perturbations, allows for highly accurate read... View Details >>
ETS-Lindgren HI-4433-CH Magnetic Field Probe 5 MHz – 300 MHz
ETS-Lindgren HI-4433-CH Magnetic Field Probe 5 MHz – 300 MHz
The HI-4433 series probes feature Automatic Continuous Zeroing. This Automatic Continuous Zeroing feature removes the need for internal zero adjustment and eliminates temperature drift errors associated with other instrumentation. The Automatic Z... View Details >>
ETS-Lindgren HI-4433-GRE Electric Field Probe 500 kHz – 5 GHz
ETS-Lindgren HI-4433-GRE Electric Field Probe 500 kHz – 5 GHz
The HI-4433 series probes feature Automatic Continuous Zeroing. This Automatic Continuous Zeroing feature removes the need for internal zero adjustment and eliminates temperature drift errors associated with other instrumentation. The Automatic Ze... View Details >>
ETS-Lindgren HI-4433-HCH Magnetic Field Probe 5 MHz – 300 MHz
ETS-Lindgren HI-4433-HCH Magnetic Field Probe 5 MHz – 300 MHz
The HI-4433 series probes feature Automatic Continuous Zeroing. This Automatic Continuous Zeroing feature removes the need for internal zero adjustment and eliminates temperature drift errors associated with other instrumentation. The Automatic Z... View Details >>

Standards

CISPR
CISPR 11
CISPR 14 - 1
CISPR 14 - 2
CISPR 14 - 2
CISPR 16 - 1
CISPR 16 - 2
CISPR 16 - 3
CISPR 16 - 4
CISPR 22
CISPR 24
IEC
IEC/TR EN 61000 - 1 - 1
IEC/TR EN 61000 - 2 - 1
IEC/TR EN 61000 - 2 - 3
IEC EN 61000 - 3 - 2
IEC EN 61000 - 3 - 4
IEC/TC EN 61000 - 3 - 5
IEC EN 61000 - 4 - 2
IEC EN 61000 - 4 - 3
IEC EN 61000 - 4 - 4
IEC EN 61000 - 4 - 5
IEC EN 61000 - 4 - 6
IEC EN 61000 - 4 - 7
IEC EN 61000 - 4 - 8
IEC EN 61000 - 4 - 9
IEC EN 61000 - 4 - 11
European
EN 50 081 part 1
EN 50 081 part 2
EN 55 011
EN 55 013
EN 55 014
EN 55 015
EN 55 020
EN 55 022
EN 55 024
EN 50 082 part 1
EN 50 082 part 2
EN 50 093
American
FCC Part 15
MIL-STD - 461E